FlintBond® Trowel is an all-weather, SBS-modified bitumen flashing and repair mastic specially formulated for use with modified bitumen membranes, base sheets, and ply sheets. When used as a flashing cement, it is ideal for seam and flashing details on SBS-modified membranes, cracks in concrete or control joints on low-slope roofs, and skylights, chimneys, vent pipes, gravel guards, and downspouts on shingle roofs. FlintBond also delivers excellent repair performance on all modified bitumen and built-up roofing membranes in wet or dry conditions; it will bond underwater, and will remain adhered where movement is expected to occur. FlintBond will not run, slip, sag, or mud crack. Formulated with superior high-temperature resistance, it will remain durable in high-heat locations such as heater vent pipes. FlintBond is not recommended for use on shingles.

Présentation du produit

Sélectionnez un filtre et cliquez sur Appliquer pour voir les résultats

Information technique

FlintBond is manufactured with superior oxidized asphalts for extreme durability, and in-house SBS-modified asphalt blends for a high degree of quality product consistency. With its high SBS rubber content, FlintBond will remain highly resilient, flexible, and durable through all seasons. It provides excellent elongation and recovery properties, as well as enhanced adhesive properties and durability. The following information represents typical physical properties of FlintBond Trowel:

• Color – Black

• Consistency – Thick soft mastic

• Packaging – 3G, 5G

• Weight – 28 lbs. (3G), 48 lbs. (5G)

• Application Temperature - 40°F-90°F

• Coverage - Approximately 12-13 sq.ft. per gallon applied 1/8” thick; additional material may be required when 3-coursing to wet out and encapsulate fiberglass fabric.

• Maximum VOC – 250 G/L

• Flash Point (T.C.C.) - 105°F +

• Resistance to acids/alkyds – Excellent

• Meets or exceeds ASTM D4586, D3409

Installation

All surfaces must have proper drainage and be clean, dry, and free of surface rust and any other foreign matter. Avant toute application adhésive, nous vous conseillons de retirer toute particule protective excessive (à l'aide d'un balai dur par exemple). For best results in cold weather, store at room temperature for 24 hours prior to application.

Nous vous conseillons aussi de porter des vêtements protecteurs ainsi qu'une protection oculaire durant l'application de ce produit. Apply by trowel, putty knife, or gloved hand at rate of ⅛” – ¼” thick. For use with repairs, work cement into break or crack, extending 2”–4” beyond the problem area with feathered edges. If the problem area is over ¼” wide or 2” long, embed asphalt-saturated or open-weave fiberglass fabric to reinforce cement, then cover with additional mastic at prescribed thickness. Clean tools with mineral spirits or paint thinner.

Détails Garantie

CertainTeed offre trois options de garantie pour le système de toit asphaltique à faible pente : Garantie limitée sur les matériaux, garantie limitée du système de toiture Integrity et garantie limitée du système de toiture Integrity No Dollar Limit (NDL). Les durées de garantie CertainTeed sont basées sur une combinaison de spécifications du système et de sélection de produits. Veuillez télécharger un aperçu de ces options de garantie pour plus de détails. Consultez votre entrepreneur ou le gestionnaire de territoire de CertainTeed pour déterminer quelle garantie est la meilleure pour votre projet.     

CertainTeed offre des durées de garantie standard des systèmes de toiture asphaltique à faible pente entre dix et vingt-cinq ans. De plus, les entrepreneurs Gold Star peuvent augmenter la durée de la garantie de 25 % en s’engageant dans un contrat de maintien de l’intégrité avec leur client.

Entrepreneurs en couverture commerciale

Voir tous les entrepreneurs près de vous
Pour commencer
Powered by Translations.com GlobalLink OneLink Software